Pultruded Grating HL-6020
Request a Quote
Please feel freely to contact with us for new price .
Greenlogy TEC
Pultruded FRP grating is made by using pultruded "I"-shaped and "T"-shaped profiles as load-bearing bars and solid tubes or rods as connecting rods, assembled through a specific assembly process, with gaps left between the panel joints.
Name | Content | Type |
|---|---|---|
Resin | 25% | OFR-25,IFR-25,VEFR-25 |
Glass fiber | 65% | E |
Filler | 8% | ATH,PR |
Other | 2% | --- |
Code | Resin type | Flame retardancy | Recommended applications |
|---|---|---|---|
MP-5 | Phenolic type | Oxygen index up to about 80 | Low toxicity and high flame retardancy; applications with very high fire safety requirements |
VEFR-25 | Vinyl ester type | Oxygen index 28 and above | Harsh environments with strong acid and alkali corrosion |
VEFR-10 | Vinyl ester type | Oxygen index 35 and above | Applications requiring high flame retardancy and resistance to strong acid and alkali corrosion |
IFR-25 | Isophthalic resin | Oxygen index 28 and above | VEFR economical type, good performance, resistant to moderate acids, alkalis and solvents |
IFGR-30 | Styrene-based (benzene-type) resin, food grade | Oxygen index 26 | Mainly used for meat products and food processing plants |
OFR-25 | Orthophthalic type | Oxygen index 28 and above | General acid and alkali environments |
OCR | Orthophthalic type | Oxygen index below 28 | OFR-25 economical type, no flame-retardant requirement |
Coarse glass fiber type selection
Code | Coarse glass fiber type | Recommended applications |
E | Alkali-free glass (E-glass) | For applications requiring high strength and high corrosion resistance |
Selected filler type
Code | Filler type | Recommended applications |
|---|---|---|
ATH | Aluminum hydroxide | Flame-retardant, smoke-suppressing and corrosion-resistant applications |
PR | No filler, pure resin | For high corrosion resistance applications |




Standard panel size:
1220mm, 915mm wide; 3050mm, 6100mm long
Load-bearing bar: 50mm
Open area: 60%
Approx. weight (incl. three-core strand): 43.5kg/m²

Line load (unit: mm)
Spacing | kg/m | kg/m | kg/m | kg/m | kg/m | kg/m | kg/m | kg/m | kg/m |
|---|---|---|---|---|---|---|---|---|---|
(mm) | 150 | 300 | 450 | 750 | 1500 | 3000 | 4500 | 6000 | 7500 |
| 600 | 0.05 | 0.1 | 0.13 | 0.23 | 0.46 | 0.89 | 1.35 | 1.78 | 2.24 |
| 750 | 0.08 | 0.15 | 0.25 | 0.4 | 0.81 | 1.63 | 2.44 | 3.28 | 4.09 |
| 900 | 0.13 | 0.28 | 0.41 | 0.69 | 1.37 | 2.74 | 4.09 | 5.46 | 6.83 |
| 1200 | 0.33 | 0.64 | 0.97 | 1.6 | 3.2 | 6.4 | 9.6 | 12.8 | 16 |

Uniform load (unit: mm)
Spacing | kg/m² | kg/m² | kg/m² | kg/m² | kg/m² | kg/m² | kg/m² | kg/m² | kg/m² |
|---|---|---|---|---|---|---|---|---|---|
(mm) | 450 | 950 | 1450 | 2450 | 4850 | 9800 | 14500 | 19500 | 24400 |
| 600 | 0.05 | 0.1 | 0.18 | 0.28 | 0.56 | 1.12 | 1.68 | 2.24 | 2.77 |
| 750 | 0.13 | 0.25 | 0.38 | 0.64 | 1.27 | 2.55 | 3.84 | 5.11 | 6.38 |
| 900 | 0.25 | 0.51 | 0.76 | 1.27 | 2.57 | 5.13 | 7.67 | 10.2 | 12.8 |
| 1200 | 0.81 | 1.6 | 2.41 | 4.01 | 8 | 16 | --- | --- | --- |
Features:
Flame retardant
High fire resistance
Low smoke and low toxicity emissions
High strength-to-weight ratio
Corrosion resistant
Low maintenance
Anti-slip
Non-conductive and non-heat-conductive
Easy to process
Impact resistant
UV resistant
Maintenance-free
Installation & Accessories

Application Scenarios
Pultruded grating is assembled using pultruded "I" and "T" profiles as load-bearing bars and solid tubes or rods as connecting rods. It is suitable for platforms, walkways, trench covers and equipment operating surfaces that require load-bearing capacity, corrosion resistance and flame retardancy. Different resin systems suit different service conditions; for specific selection, please contact us to confirm based on your actual working conditions.
Selection Guide
Selection mainly depends on media corrosiveness, load-bearing requirements and fire protection requirements: phenolic types have a high oxygen index and are suitable for applications with high requirements for low toxicity, high flame retardancy and fire safety; vinyl ester types offer good corrosion resistance and are suitable for common acid and alkali environments. Welcome to contact us for detailed specifications and quotations; we will help match the resin type and grating structure.
Product Advantages
Assembled from pultruded profiles, the panels are lightweight, high-strength, corrosion-resistant and easy to cut and install on site, reducing later maintenance. The open-gap structure between profiles and connecting rods accommodates both load bearing and drainage and ventilation, making it suitable for a variety of industrial environments.
Inquiry Guide
For specific information on the size, resin type, load bearing and delivery time of pultruded grating HL-6020, please contact us. We will provide detailed specifications and quotations based on your working conditions.
Service Environment
- Pultruded FRP grating HL-6020 uses pultruded I-type and T-type load-bearing bars as its framework, connected with solid tubes or solid rods as connecting rods. This structure is suitable for walking surfaces where steel materials would corrode.
- The phenolic MP-5 resin option is formulated for low-toxicity, high-flame-retardancy applications and is suitable for indoor and outdoor locations with fire safety requirements.
- The vinyl ester and other resin systems in the series are selected for service conditions involving long-term exposure to damp, chemical-containing or other corrosive environments.
- Typical application locations include platform walkways, stair treads and inspection covers in industrial plants; please contact us and provide your site conditions to obtain the complete parameter table.
Custom Cutting
Need panels that fit, or cut to shape? We custom cut FRP grating and profiles to your drawing: panels cut to size or to shape (corner cuts, cutouts), cut edges sealed with resin, and pre-cut and pre-drilled to drawing before shipping. See the custom cutting services.
简体中文